Customizable FM200 Gas Suppression System with 800m² Single-Zone Protection and ≤10s Spraying Time for Industrial FM200 Fire Suppression System

Guangzhou Xingjin Fire Equipment Co.,Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Customizable FM200 Gas Suppression System with 800m² Single-Zone Protection and ≤10s Spraying Time for Industrial FM200 Fire Suppression System

Scale of Protective region for one zone : area:max single-zone is 800m² volume: max single-zone is 3600m³

Spraying time : ≤10s

Nitrogen Pressure of Driving De vice : 6.0±1.0MPa(20℃)

min working pressure : 4.2Mpa/4.6Mpa

Filling density : ≤950kg/m3,≤1080kg/m3

Condition of reserving room for container : temperature: -10~50℃, relative humidity: ≤97%

power : DC24V/1.6A

Filling pressure : 4.2Mpa/5.6Mpa

max working pressure : 5.3Mpa/8.0Mpa

Brand Name : XINGJIN

Model Number : 4.2MPa/5.6MPa

Certification : CCC,ROHS,CAC

Place of Origin : Guangzhou,China

MOQ : 10 set system

Price : USD480-520/set

Payment Terms : T/T,L/C

Supply Ability : 30000set/month

Delivery Time : 15-20days

Packaging Details : Wooden Box Or Plywood Outer Box With Bubble Bag Or Paper

Contact Now

Pipeline Gas Fire Extinguishing System (5.6 MPa)

Heptafluoropropane (chemical formula CF₃CH₂F) is a colorless, odorless, non-conductive extinguishing agent that produces no secondary pollution. Its ozone depletion potential (ODP) is zero. Among the ISO-approved clean gas fire extinguishing agents, it offers excellent cleanliness, low toxicity, good electrical insulation properties, and high fire suppression efficiency.

The heptafluoropropane fire extinguishing mechanism operates through three complementary actions:

  • Chemical inhibition: The agent inertizes active free radicals in the flame, blocking the chain reaction during combustion.
  • Cooling: When the liquid agent is discharged from the nozzle, it rapidly transforms into a gaseous state, absorbing a large amount of heat and reducing the temperature of the flame area within the protected zone.
  • Suffocation: The release of the agent within the protected area reduces the oxygen concentration, slowing the burning rate.

The heptafluoropropane fire extinguishing equipment is submitted for inspection and certification in accordance with the GB25972-2010 standard. Its system functions are complete, operation is reliable, safety protection measures are comprehensive, and it is widely used for the protection of multiple and large protected areas.

Customizable FM200 Gas Suppression System with 800m² Single-Zone Protection and ≤10s Spraying Time for Industrial FM200 Fire Suppression System
Scope of Application

The system can be used to extinguish the following types of fires:

  • Electrical fires
  • Liquid fires or fires involving molten solids
  • Fires on the surface of objects
  • Gas fires whose gas source can be cut off before extinguishing

It is suitable for protecting enclosed spaces. Typical protected locations include:

  • Fire protection zones for gases and liquids with explosion hazards
  • Libraries, archives, document and cultural relic repositories
  • Oil-immersed transformers, oil-filled power distribution equipment, and standby generator rooms
  • Communication rooms and computer rooms
Customizable FM200 Gas Suppression System with 800m² Single-Zone Protection and ≤10s Spraying Time for Industrial FM200 Fire Suppression System
System Technical Parameters
Storage Pressure 5.6 MPa
Extinguishing Agent Discharge Time ≤ 10 s
Extinguishing Agent Filling Density ≤ 1080 kg/m³
Drive Device Air Source Pressure 6.0 MPa (at 20℃)
System Working Power Supply AC 220V / DC 24V, 1A
System Working Environment Temperature 0℃ ~ 50℃
System Protection Limit Area: Maximum single zone 800 m²
Volume: Maximum single zone 3600 m³
System Startup Mode Automatic, electrical manual, mechanical emergency manual
Storage Bottle Volume 70 L, 90 L, 120 L
Why Choose Us
Customizable FM200 Gas Suppression System with 800m² Single-Zone Protection and ≤10s Spraying Time for Industrial FM200 Fire Suppression System

Product Tags:

5.6Mpa Storage Pressure FM200 Gas Suppression System

      

≤10s Discharge Time FM200 Fire Extinguishing System

      

800m² Single Zone Protection Heptafluoropropane Fire Suppression System

      
Quality Customizable FM200 Gas Suppression System with 800m² Single-Zone Protection and ≤10s Spraying Time for Industrial FM200 Fire Suppression System for sale

Customizable FM200 Gas Suppression System with 800m² Single-Zone Protection and ≤10s Spraying Time for Industrial FM200 Fire Suppression System Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Guangzhou Xingjin Fire Equipment Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)